• en

  • HOME
  • THE GROUP
    • Company
    • History
    • Vision
    • visitus.fedegari
  • MANUFACTURING
    • Quality Certification
    • Why Fedegari
  • PRODUCTS
    • Industrial
    • Lab Equipment
    • Integrated Systems
  • SERVICES
    • Tech Center
    • After-Sales
    • Training
  • NEWS
  • MEDIA
    • Case studies
    • Catalogues
    • Documents
    • E-Book
    • Video
    • White Paper
  • CONTACTS
    • Contact Us
    • Where we are
    • Careers

  • HOME
  • THE GROUP
    • Company
    • History
    • Vision
    • visitus.fedegari
  • MANUFACTURING
    • Quality Certification
    • Why Fedegari
  • PRODUCTS
    • Industrial
    • Lab Equipment
    • Integrated Systems
  • SERVICES
    • Tech Center
    • After-Sales
    • Training
  • NEWS
  • MEDIA
    • Case studies
    • Catalogues
    • Documents
    • E-Book
    • Video
    • White Paper
  • CONTACTS
    • Contact Us
    • Where we are
    • Careers
en
    PDA - Validation of Moist Heat Sterilization Processes
    PDA-Validation of Moist Heat Sterilization Processes
    4 March 2021
    Fedegari hosts PDA hands-on training at our Tech Center in Sellersville (PA)

    Fedegari hosts PDA hands-on training at our Tech Center in Sellersville (PA)

    Fedegari hosts PDA hands-on training at our Tech Center in Sellersville (PA)

    PDA Training at Fedegari Tech Center

    Last week, from 23rd to 25th of March, we hosted PDA – Parenteral Drug Association training – Validation of Moist Heat Sterilization Processes – at Fedegari Tech Center in Sellersville (PA). It was simply great to experience our US brand-new expanded facilities together with our guests.

    Learning how to validate sterilization processes

    Following all the anti-COVID19 rules to keep our attendees safe, we managed to give them the possibility to interact in the best way possible sharing knowledge through practical examples of moist-heat sterilization on Fedegari machines.

    Participants had interesting discussions about Microbiology, Thermal Science & Steam Quality, FAT, SAT, Sterile Process Development, Process Performance Qualification & Ongoing Control. Each module has been followed by a Lab Work and demonstrations with our autoclaves and sterilizers.

    The class partecipated in brainstorming over possible solutions sharing opinions in an open-discussion at the end of the course.

    Fedegari Trainings

    We hold different trainings according to customers needs. Besides following the latest updates in the Pharma World, we continuously make new processes applications from the real experience with customers. This is the reason why our trainings are in constant evolution.
    We look forward sharing our knowledge from the latest case studies with you.

    Explore our trainings

    Fedegari Tech Center

    Everything was possible also thanks to the expansion of our facility in Sellersville.
    The training sessions explored what our new US facility offers after its latest 20,000 ft2 expansion. In addition to a new automated warehouse and office space, we have built a new training center. It offers cutting edge education technology and an expanded hands-on showroom that will now house examples of each of our product lines: washers, sterilizers, isolators, decontamination units, and other machines.

     

    Learn more

    Some photos of PDA Training at Fedegari Tech center

    We learn from our customers everyday.

    We share these experiences at our trainings.

    Discover the knowledge that fits your needs.

    training@fedegari.com

    E-training

    Understanding Moist Heat Sterilization and Validation Aspects

    Principles, Application & Challenges

    1
    Basics of sterilization
    2
    Understanding sterility assurance concepts, D-value, Z-value, F0
    3
    How to select the appropriate steam sterilizer according to the load type

    4
    Treatment of porous and liquid loads

    5
    Main factors that strongly impact the outcome of a sterilization process

    6
    Selecting the validation methodologies according to load attributes: overkill, bioburden/biological indicator and bioburden-based approach

    7
    Defining the “worst case” load

    8
    Performing physical and microbiological studies

    9
    Validation equipment (TC’s, CI’s, BI’s): selection, placement and results interpretation

    Contact Fedegari
    FCDV_prodotto_fedegari

    E-training

    Insights in Chemical Bio-Decontamination

    Design, Application & Validation of H2O2 Processes

    1
    Overview of vaporized hydrogen peroxide technology
    2
    Critical process parameters and examples of relevant case studies

    3
    Validation activities: enclosure evaluation and CI’s, BI’s and TC’s utilization

    Contact Fedegari
    FCTS_fedegari_product

    E-training

    Overcoming Challenges in a Sterility Testing Isolator

    Testing Procedures and Environmental Monitorin

    1
    Guidance on conducting sterility testing and environmental monitoring
    2
    Practical advice on consumables, equipment, design, application and challenges

    3
    Achievieng the highest level of safety and testing confidence

    Contact Fedegari

    Do you need more information?

    Contact us to create your own program. We can deliver you a unique learning experience.

    Request your customized training offer to acquire deeper knowledge about specific subjects.

    We will cover the science behind the processes and practical advice to guarantee the highest performances to your team.

    Contact our team today!
    Share

    Related posts

    PDA - Validation of Moist Heat Sterilization Processes

    PDA - Validation of Moist Heat Sterilization Processes

    4 March 2021

    PDA-Validation of Moist Heat Sterilization Processes


    MORE
    Digital Transformation Conference

    Digital Transformation Conference at Università degli Studi di Pavia

    19 February 2021

    3rd International Conference “𝗖𝗼𝗺𝗽𝗲𝘁𝗶𝘁𝗶𝘃𝗲 𝗥𝗲𝗻𝗮𝗶𝘀𝘀𝗮𝗻𝗰𝗲 𝘁𝗵𝗿𝗼𝘂𝗴𝗵 𝗗𝗶𝗴𝗶𝘁𝗮𝗹 𝗧𝗿𝗮𝗻𝘀𝗳𝗼𝗿𝗺𝗮𝘁𝗶𝗼𝗻”


    MORE
    Chef Mirko and the Fedegari Canteen team

    Chef Mirko and the Fedegari Canteen team

    11 February 2021

    Hell’s Kitchen winner to create a new food experience for Fedegari employees and customers


    MORE
    fedegari
     

     
    HOME

    THE GROUP
    Company
    History
    Vision

    MANUFACTURING
    Quality Certification
    Why Fedegari

     
    PRODUCTS
    Industrial
    Lab equipment
    Integrated systems

    SERVICES
    Tech Center
    After-Sales
    Training

    CONTACTS

    NEWSLETTER

     
    HEADQUARTER
    Fedegari Autoclavi SpA
    SS 235 km 8
    27010 Albuzzano (PV) Italy

    T +39 0382 434111
    fedegari@fedegari.com

    Fedegari Creative Projects

    MEDIA PARTNER


    Fedegari Autoclavi S.p.A. - P.IVA 00303010185 - fedegari@fedegari.com - tel +39 0382 434111 - fax +39 0382 434150 - copyright © 2019-2020 creativesoul.it

      0English
      • No translations available for this page
        Cookie Policy
        This site makes use of technical, analytics and profiling cookies, also managed by third parties. These cookies help us to provide a qualified service. To find out more or reject all/some cookies, please press "more information". By continuing on this browse you accept our cookies policy.

        OK More information NO
        Privacy & Cookies Policy

        Privacy Overview

        This website uses cookies to improve your experience while you navigate through the website. Out of these cookies, the cookies that are categorized as necessary are stored on your browser as they are as essential for the working of basic functionalities of the website. We also use third-party cookies that help us analyze and understand how you use this website. These cookies will be stored in your browser only with your consent. You also have the option to opt-out of these cookies. But opting out of some of these cookies may have an effect on your browsing experience.
        Necessary
        Always Enabled

        Necessary cookies are absolutely essential for the website to function properly. This category only includes cookies that ensures basic functionalities and security features of the website. These cookies do not store any personal information.

        SAVE & ACCEPT
        Subscribe to our newsletter - Personal Data Therms
        Your data will be processed for communications and marketing purposes, including commercial communications, events organization, advertising, market research and statistical analysis for marketing purposes.
        Your details will not be communicated or disclosed to third parties, and you may require at any time, the access, the rectification, the erasure, the restriction, the portability and to object their use (according to Articles 15, 16, 17, 18, 20, 21) by sending an e-mail privacy@fedegari.com.
        Personal data information
        I authorize the use of my personal data in compliance with UE Regulation n.67/2016 on the protection of natural persons with regard to the processing of personal data (GDPR).
        My details will not be communicated or disclosed to third parties , and I may require at any time, the access, the rectification, the erasure, the restriction, the portability and to object their use (according to Articles 15, 16, 17, 18, 20, 21) by sending an e-mail privacy@fedegari.com.